1. Menjajarkan cahaya mikroskop metalurgi

Dengan tangan kiri, putar skru pelarasan kasar untuk membuat tong kanta naik atau platform pembawa ke bawah, dan kemudian putar penukar objektif untuk menjadikan kanta pembesaran rendah sejajar dengan platform pembawa melalui lubang cahaya (putaran harus berhati-hati untuk buat kanta objektif di atas kekurangan ukiran dan pangkal gancu gesper tetap), buka apertur, putar skru pengangkat kanta pengumpul, supaya cermin pengumpul di hujung atas satah kanta lebih rendah sedikit daripada ketinggian satah platform pembawa, kedua-dua mata pada masa yang sama, sambil melaraskan arah pemantul sehingga medan pandangan Cahaya adalah sekata dan kecerahan adalah sederhana.

 

2. Mikroskop metalografikPenempatan spesimen slaid

Ambil spesimen slaid dan letakkan di atas pentas pembawa dengan bahagian slip penutup menghadap ke atas, pasangkannya pada penolak, kemudian putar skru penolak dengan tangan untuk menjajarkan spesimen yang akan diperhatikan dengan tengah apertur.

 

3. Mikroskop metalografikMelaraskan fokus

Putar skru pelarasan kasar dengan tangan, buat kanta pembesaran rendah<6mm from the slide specimen (when adjusting the distance between the objective lens and the slide must be watched from the side, do not turn the coarse adjustment screw at the same time as observing with your eyes on the eyepiece to prevent the lens from colliding with the slide and causing damage), and then open your eyes at the same time, turn the coarse adjustment screw slowly by hand so that the lens rises or make the carrier table fall, when the object image in the field of view is viewed, then adjust the fine adjustment screw until a clear object image appears in the field of view. When the object image appears in the field of view, adjust the fine adjustment screw until a clear object image appears in the field of view. If the object image is not in the centre of the field of view, move the slide specimen up and down, left and right (Note: the direction of movement of the slide is opposite to the direction of movement of the observed object image). If the distance between the lens and the specimen slice has exceeded the working distance when adjusting the focal length and the object image is not seen, then it should be reopened strictly according to the above steps.

 

4 Electronic Magnifier

 

 

 

 

 

Hantar pertanyaan